• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@MEF
  • Fakülteler
  • Mühendislik Fakültesi
  • Makine Mühendisliği | Mechanical Engineering
  • MF, MM, Bildiri ve Sunum Koleksiyonu
  • Öğe Göster
  •   DSpace@MEF
  • Fakülteler
  • Mühendislik Fakültesi
  • Makine Mühendisliği | Mechanical Engineering
  • MF, MM, Bildiri ve Sunum Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.
Gelişmiş Arama

Calibration of the effective spring constant of ultra-short cantilevers for a high-speed atomic force microscope

Thumbnail

Göster/Aç

Yayıncı Sürümü - Makale (1.876Mb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2015

Yazar

Song, Yun-Peng
Wu, Sen
Xu, Lin-Yan
Zhang, Jun-Ming
Dorantes-Gonzalez, Dante Jorge
Fu, Xing
Hu, Xiao-Dong

Üst veri

Tüm öğe kaydını göster

Künye

Song, Y.-P., Wu, S., Xu, L.-Y., Zhang, J.-M., Dorantes-Gonzalez, D. J., Fu, X., & Hu, X.-D. (June 01, 2015). Calibration of the effective spring constant of ultra-short cantilevers for a high-speed atomic force microscope. Measurement Science and Technology, 26, 6, 65001.

Özet

Ultra-short cantilevers are a new type of cantilever designed for the next generation of high-speed atomic force microscope (HS-AFM). Ultra-short cantilevers have smaller dimensions and higher resonant frequency than conventional AFM cantilevers. Moreover, their geometry may also be different from the conventional beam-shape or V-shape. These changes increase the difficulty of determining the spring constant for ultra-short cantilevers, and hence limit the accuracy and precision of force measurement based on a HS-AFM. This paper presents an experimental method to calibrate the effective spring constant of ultra-short cantilevers. By using a home-made AFM head, the cantilever is bent against an electromagnetic compensation balance under servo control. Meanwhile the bending force and the cantilever deflection are synchronously measured by the balance and the optical lever in the AFM head, respectively. Then the effective spring constant is simply determined as the ratio of the force to the corresponding deflection. Four ultra-short trapezoid shape cantilevers were calibrated using this method. A quantitative uncertainty analysis showed that the combined relative standard uncertainty of the calibration result is less than 2%, which is better than the uncertainty of any previously reported techniques.

Kaynak

Measurement Science And Technology

Cilt

26

Sayı

6

Bağlantı

http://dx.doi.org/10.1088/0957-0233/26/6/065001
https://hdl.handle.net/20.500.11779/639

Koleksiyonlar

  • Araştırma Çıktıları, Scopus İndeksli Yayınlar Koleksiyonu [429]
  • Araştırma Çıktıları, WOS İndeksli Yayınlar Koleksiyonu [470]
  • MF, MM, Bildiri ve Sunum Koleksiyonu [15]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@MEF

by OpenAIRE

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreKurum Yazarına GöreBaşlığa GöreORCID'e GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliBu KoleksiyonTarihe GöreYazara GöreKurum Yazarına GöreBaşlığa GöreORCID'e GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim Şekli

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || MEF Üniversitesi || OAI-PMH ||

MEF Üniversitesi Kütüphanesi, İstanbul, Türkiye
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

Creative Commons License
MEF Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@MEF:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.